The number in this technology mark refers to the approximate quantity of ions per cm3 of air released from the dehumidifier equipped with a high-concentration Plasmacluster ion generating unit which was measured at the center point ( 1.2 meter height above the floor ) of high-concentration Plasmacluster 7,000 applicable floor area room ( temperature 28 °C, humidity 50 % ) when the dehumidifier was placed against the wall and runs in laundry mode and the swing louver is set to full open position .

Device of this mark is a trademark of Sharp Corporation.
Plasmacluster is a registered trademark or a trademark of Sharp Corporation.

Do not use the product for commercial purposes .

FEATURES

The dehumidifier deodorizes, cleans and quickly dries clothes hung up in the room by using the high-concentration Plasmacluster Ion ( PCI ) technology and the powerful dehumidifying function .The number in this technology mark refers to the approximate quantity of ions per cm3 of air released from the dehumidifier equipped with a high-concentration Plasmacluster ion generating unit which was measured at the center point ( 1.2 meter height above the floor ) of high-concentration Plasmacluster 7,000 applicable floor area room ( temperature 28 °C, humidity 50 % ) when the dehumidifier was placed against the wall and runs in laundry mode and the swing louver is set to full open position .

SAFETY PRECAUTIONS

To prevent any possible injury to persons or damage to property, be sure to follow the basic safety precautions, including the following :The degree of injury or damage resulting from incorrect use or operation while ignoring the indicated matters is classified and explained with the following symbols .

WARNINGS: Indicates a potentially hazardous situation which, if not avoided, could result in serious injuries or even death.

CAUTION: Indicates a potentially hazardous situation which, if not avoided, could result in personal injury or property damage.

The precautions to be observed are indicated with the following symbols and signs .

Indicates a prohibited action .Indicates a mandatory action .

WARNING

Power Plug, Power Cord

  • Do not connect the unit from extension cord or multiple wiring with other electronic appliances.
    (Otherwise, electric shock, fire or overheat may be caused.)
  • Do not damage the power cord.
  • Do not process, forcibly bend, pull by force, twist or bind the power cord.
  • Do not place heavy objects on the power cord, or apply too much force to it.
  • Do not attempt to replace the power cord on your own.
  • Do not damage the power cord while moving the unit on its casters.
    (Otherwise, fire or electric shock may be caused.)
  • Do not use other than the rated voltage 220V (50Hz).
  • Do not operate or stop the unit by using the power plug.
    (Otherwise, electric shock or fire may be caused.)
  • In case of an exception (e.g., burnt smell), be sure to immediately shut the unit down and remove its power plug.
  • Make sure there is no dust on the power plug and insert it into the outlet completely. Any dust around the power plug should be wiped off with a dry cloth periodically.
    (Accumulated dust may result in poor insulation from humidity, etc., thereby causing fire or electric shock.)
  • If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard. This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.

Main Unit

  • Do not make modifications. Disassembly, repairing, modifications shall not be made by a person other than the service engineer.
    (Otherwise, fire, electric shock or injury may be caused.)

  • Do not place spray cans close to the main unit. (Besides, do not use flammable hazardous materials (gasoline, thinner, etc.) near the main unit. Otherwise, ignition of fire, explosion may occur.)
  • Do not put fingers or foreign objects (pin, needle, stick, etc.) into the air outlet or air intake.
    (The fan is rotating at high speed inside. Injury, electric shock and malfunction may occur.)
  • Do not place the unit near heating appliances.
    (Otherwise, plastic parts will melt and fire ignition may occur.)

CAUTION

Power Plug, Power Cord

  • Always hold the power plug when unplugging the unit.
    (Otherwise, fire, electric shock, short circuit may occur.)
  • If you are planning not to use the unit for a long time, unplug the power plug from outlet for safety.
    (Otherwise, electric shock, electric leakage or fire may be caused.)
  • During maintenance, be sure to power off the dehumidifier and remove the power plug from the socket

During Usage

  • For the vulnerable floor, uneven floor or long wool carpet, lift the main unit
    when you move it. (Otherwise, the floor or carpet may be scratched).
  • Do not overturn or drop the main unit. Do not store or move the dehumidifier when the main unit is overturned. (Otherwise, equipment damage or malfunction such as water/electric leakage
    may be caused.)
  • Do not use the dehumidifier in a narrow place, for example, the gap of a closet or furniture.
  • Prevent cloth or other objects from obstructing the air outlet or inlet.
    (Poor ventilation may lead to overheating or fire.)

  • Do not rinse the main unit with water.
  • Do not place an object with water such as a vase on top of the main unit.
  • For indoor use only. Do not use the unit under direct sunlight or in any location exposed to rain and wind.
  • Do not leave the unit where oil or flammable gas may leak.
    (Otherwise, electric shock, overheating, electric leakage or fire may be caused.)
  • Do not expose the air from this product directly to heating appliances.
    (Otherwise, incomplete combustion of heating may be caused.)
  • Do not stand or lean on the main unit.
    (Otherwise, injury may be caused from moving or falling.)
  • Do not use the drained water for drinking or feeding.
    (Otherwise, health problems may be caused.)
  • Do not use for storage/special purpose for artworks or academic materials.
    (Otherwise, quality degradation of stored materials may be caused.)
  • Before moving the main unit, always stop the operation and dispose the water in the water tank.
    Operate the unit only on level, stable surfaces.
    (If water leaks from the dehumidifier and soaks the furniture in the room, electric shock, electric leakage or fire may be caused.)
  • Always have plenty of room around the main unit.
    (Poor ventilation may cause over-heating, fire, malfunction.)
  • Be sure to clean the product, floor and surroundings when using the product in a same place for a long period of time.
    (Move the dehumidifier and clean the ground from time to time.)
  • Do not remove the water tank while the dehumidifier is operating.
    (Otherwise, water may drop on the floor or carpet.)

PARTS NAME

Front View

Back View

BEFORE USE

INSTALLATION LOCATION

WHAT YOU NEED TO KNOW

WHEN MOVING

NOTE: For the vulnerable floor, uneven floor or long wool carpet, lift the main unit when you move it;
otherwise, the floor or carpet surface may be damaged.

HOW TO OPERATE

AUTO DEFROST

  • During defrosting, the defrosting indicator is on, the compressor stops, and the fan keeps rotating at the highest speed. After the defrosting ends, the dehumidifying function starts, the compressor restarts, and the fan resumes the preset speed.
  • When the temperature sensor fixed on the copper pipe of evaporator detects that the dehumidifier temperature is lower than or equal to -1°C (and the relative room temperature is lower than or equal to 13°C), the dehumidifier will start the automatic defrosting procedure, namely, the dehumidifier defrosts automatically after the dehumidifying mode runs for 20 minutes; when the evaporator surface is defrosted completely, the temperature sensor detects that the temperature is higher than or equal to 2°C and the defrosting duration is longer than or equal to 10 minutes, the dehumidifier will stop defrosting and enable the dehumidifying function.

COMPRESSOR STOP / START PROTECTION

  • During operation, if the compressor stops due to any operation, the dehumidifier will automatically switch to the function of restarting the compressor after stopping it for 3 minutes, namely, the compressor cannot be restarted in 3 minutes, but other functions are available.
  • In the dehumidifying mode, if you remove and replace the water tank or power off and power back on the dehumidifier, the dehumidifying function will start after an interval of 3 minutes.

CONTROL PANEL

EASY-TO-USE FUNCTIONS

After you insert the power plug, all the LED indicators and digital display are on for 1 second and then turn off. Meanwhile, the buzzer sends three alert sounds. Each time you press a button, the buzzer sends a alert tone. When you press the ON / OFF button to power the unit off, the buzzer sends a long beep sound .

OTHER FUNCTIONS

AUTO STOP AT TANK FULL

  •  If the water in the water tank reaches the set level when the dehumidifier operates in the dehumidifying mode, both the compressor and the fan motor stop running, the unit stops operation the buzzer sends out ten warning sounds, and only the Tank full indicator is on.

POWER FAILURE MEMORY

  •  After you power off the unit by pressing the ON/OFF button, when you power it back on by pressing the same button, the dehumidifier will begin operating with the mode before it is powered off.
    If power fails while the dehumidifier is operating (i.e. the power plug is removed), the dehumidifier will memorize the operating mode before the power failure and resume this mode automatically after it is powered back on.

LOW/HIGH TEMPERATURE PROTECTION

  • The function eliminates the risk that the dehumidifier may operate in an abnormal environment. When the temperature/humidity sensor of the air inlet detects that the current ambient temperature is lower than or equal to 0°C or higher than or equal to 40°C (including open circuit or short circuit of the temperature sensor (NTC)), the dehumidifier will stop running and enable the over-temperature protection function. The buzzer keeps sending out three long and two short warning tones, all the indicators turn off, and only the digital display blinks and shows C1.

  • When the temperature sensor of the copper pipe of evaporator detects that its temperature is higher thanor equal to 40°C within two continuous minutes, the dehumidifier will stop running and enable the over-temperature protection function. All the indicators turn off, only the digital display blinks and shows C2, none of the buttons work, and the buzzer does not beeps. In this case, you must power off and back on the dehumidifier.

HOW TO DRAIN

After the water tank is removed, the Tank full indicator is on and the operation stops .

Note: 

  • Always stop the operation and dispose water before moving the main unit.
    (Water in the tank may spill and damage household goods.)
  • Clean the inside of water tank periodically (about once a week).
    (Failing to clean for a long period of time may increase mold and bacteria which causes bad odor.)

CONTINUOUS DRAINPIPE

CARE AND MAINTENANCE

We recommend periodical cleaning for a long, clean and sanitary use !

AIR INLET Once Week

FOR HEAVY DUST

WATER TANK

MAIN UNIT

Use a soft cloth soaked with warm water ( lower than 35 °C ) or neutral detergent ( for tableware ) to wipe dirt from the surface .

NOTE: 

  • Poor insulation or rust may occur if the main unit gets wet.
  • When using chemical agent, please follow the direction for use.
  • Do not use materials that harm plastics, for example, diluent, gasoline, alcohol, petroleum, soap, lapping powder, alkaline detergent, hot water and acid.

WHEN NOT USING FOR A LONG PERIOD OF TIME

SPECIFICATIONS

The dehumidifying capability : the amount of humidity that a dehumidifier removes from the air in a day when room temperature and relative humidity are kept at 30 °C / 80 % RH and 26.7 °C / 60 % RH respectively .Please be well noted that the product specifications are subject to change without a prior notice .

TROUBLESHOOTING

 